Leave Your Message

Products

NH Series Low Voltage Hrc Fuse Knife Type Contact FuseNH Series Low Voltage Hrc Fuse Knife Type Contact Fuse
01

NH Series Low Voltage Hrc Fuse Knife Type Contact Fuse

2024-11-06

NH series low-voltage fuses are widely used as protective electrical appliances in low-voltage distribution systems and motor control circuits. Its main function is to quickly melt the fuse in the circuit or equipment when it is overloaded or short circuited, thereby cutting off the circuit and providing short-circuit protection.

view detail
Wedge Type Contact Fuse, J Type Fuse, Lv Cut out FuseWedge Type Contact Fuse, J Type Fuse, Lv Cut out Fuse
01

Wedge Type Contact Fuse, J Type Fuse, Lv Cut out Fuse

2024-12-06

Wedge type contact fuse, J type fuse, LV cut out fuse is mainly used in AC voltage 415V power grid systems, with a breaking capacity of up to 80kA, complying with standards IEC60269, BS88, widely used in Africa, America, Europe and other regions

view detail
CZFSD Series Outdoor Fuse Isolation SwitchCZFSD Series Outdoor Fuse Isolation Switch
01

CZFSD Series Outdoor Fuse Isolation Switch

2024-12-06

CZFSD series outdoor fuse isolation switch, suspended on outdoor utility poles, modular design, current divided into 160A, 400A, 630A, A3 types, voltage from AC 220V to 690V, matched with LV HRC NH series fuses.

view detail
High-Quality LV Fuse Switch Disconnector for Reliable Power ManagementHigh-Quality LV Fuse Switch Disconnector for Reliable Power Management
01

High-Quality LV Fuse Switch Disconnector for Reliable Power Management

2024-12-06

HR17 series fuse type isolating switch (hereinafter referred to as the switch).
Mainly used for rated voltage AC 380V-690V (45-62Hz). Agreed heating and power generation In the distribution circuit and motor circuit with high short-circuit current flowing to 800A, As a power switch, isolation switch, emergency switch, and also used for circuit protection, But it is generally not used for directly opening and closing a single motor.
This product meets the performance standards of IEC947-3 and GB14048.3.

view detail
HH15 (QSA) Series Switch Disconnector FuseHH15 (QSA) Series Switch Disconnector Fuse
01

HH15 (QSA) Series Switch Disconnector Fuse

2024-12-06

Mainly used in distribution circuits and motor circuits with high short-circuit currents, as manual and infrequent.
The main switch or master switch for operation is particularly suitable for installation in higher-level drawer type low-voltage complete sets of equipment. Double investment Switches are used for infrequent connection and disconnection of dual electrical circuits.
This product meets the performance standards of IEC947-3

view detail
DC Fuses for Overcurrent Protection in Solar Photovoltaic SystemsDC Fuses for Overcurrent Protection in Solar Photovoltaic Systems
01

DC Fuses for Overcurrent Protection in Solar Photovoltaic Systems

2024-12-06

This series of fuses is suitable for use in circuits with rated DC voltage up to 1500V and rated current up to 63A, in conjunction with photovoltaic panels and energy storage systems.
Connect batteries in series and parallel to provide short-circuit protection for the charging converter system; At the same time, for photovoltaic power plants, the convergence inverter rectification system and short circuit.
Road fault disconnection protection; As well as providing surge current and short-circuit fault overvoltage rapid breaking protection for photovoltaic power generation systems, rated breaking.
Capable of up to 33kA, the product complies with the national standard GB/T13539.6 and the International Electrotechnical Commission standard IEC60269-6.

view detail
Fast Melting Link for DC Protection of New Energy (Charging Pile, Energy Storage)Fast Melting Link for DC Protection of New Energy (Charging Pile, Energy Storage)
01

Fast Melting Link for DC Protection of New Energy (Charging Pile, Energy Storage)

2024-12-06

This series of fuses is suitable for use in circuits with DC rated voltage up to 1000V and rated current up to 800A, as an electric vehicle.
Drive power systems, power conversion systems, energy storage and power systems, variable frequency controllers, charging stations, and other automotive components.
The short circuit and overload protection of the equipment has a rated breaking capacity of up to 50kA. The product complies with national standard GB/T13539.4 and international electrical standards.
According to the IEC 60269-4 standard.

view detail
Top Switch Disconnectors: Safety, Features, and Buying GuideTop Switch Disconnectors: Safety, Features, and Buying Guide
01

Top Switch Disconnectors: Safety, Features, and Buying Guide

2024-12-06

The HGL series Switch disconnector is  mainly used in circuits with AC 50Hz rated voltage of 380V and rated current up to 3150A. Used for infrequent connection and disconnection of circuits and electrical isolation.

view detail
High Voltage Current Limiting FuseHigh Voltage Current Limiting Fuse
01

High Voltage Current Limiting Fuse

2024-12-06

This series of product is applied to power system with indoor AC 50Hz-60Hz, rated voltage being 3.6Kv-40.5Kv, and it could be cooperation-used with other protection electric device (such as vacuum connector. load switch ect) to be overload or short circuits protection components of high-voltage motor, power transfomer, instruments transformer, and other electical equipment.

view detail
"KB, KU, KS" Type of Fuse Wire (Fuse Link)"KB, KU, KS" Type of Fuse Wire (Fuse Link)
01

"KB, KU, KS" Type of Fuse Wire (Fuse Link)

2024-12-06

"KB, KU, Ks" type fuses belong to “K" and“T”
H ”type fuse, it has general type, universal type and screw type available according to IEC-282 standard.Tkey are suitabe for dropoff fuse cut out with rated voltage 11-36kv.

view detail